16
The calibrated dial reads 0 to 100. The majority of
recorded measurements will be within this range
and are readjust as the graduation appears on the
dial.
However, on high load measurements, it is possi-
ble for the needle to make one complete revolution
past zero. For these readings, it is necessary to add
100 to the graduation indicated by the needle.
Dial
Accurate strand tension measurement requires that
a section of strand be at least twenty feet long and
free from damage or corrosion. If cable is in place,
remove one ring or cable support or un-lash suffi-
ciently to obtain about two feet of unobstructed
strand.
Suspend the instrument on the strand by the hooks
located at each end of the tension bar with the han-
dle projecting downward.
With the unit in position, always check to make
certain that the dial indicator reads zero. If the dial
indicator does not read zero, loosen the slotted
screw located in the dial shroud. Rotate the dial
slightly until the dial indicator reads zero and re-
tighten the screw. As an alternate to "re-zeroing"
the unit each time the installed position of the Ten-
sionmeter is changed, place the unit in the position
in which it is to be used and note the number of
graduations above or below the zero mark. Once
the Tensionmeter is installed and set, add or sub-
tract those graduations to/from the dial reading be-
fore referring to the chart.